Abbott Celldyne 3500 R

     
Type
:
Hematology Analyzer
Parameters
:
22; 5-pt Differential
Throughput
:
90 samples / hour
Method
:
Volume Impedance
Open system
:
YES
Others
:
Report in 40 seconds
Automated retics
 
 
         
 
 
 
   

Bayer Advia 60

     
Type
:
Hematology Analyzer
Parameters
:
18, 3-pt Differential
Throughput
:
60 samples / hour
Method
:
Volume Impedance
Open system
:
YES
 
         
 
 
 

Olympus AU400

     
Type
:
Chemistry Analyzer
Parameters
:
99 analytes
Throughput
:
400 samples / hour; 800 w/ise
Method
:
Spectrophotometric
Open system
:
YES
   
         
 
 
   

Roche Hitachi 902

     
Type
:
Chemistry Analyzer
Parameters
:
69 analytes
Throughput
:
200 samples / hour; 300 w/ise
Method
:
Spectrophotometric
Open system
:
YES
 
         
 
 

Roche Cobas Mira Plus

     
Type
:
Chemistry Analyzer
Parameters
:
65 analytes
Throughput
:
144 samples / hour
Method
:
Filter Photometric
Open system
:
YES
Others
:
First in India
   
 
 
 
   

Bayer Advia Centaur

     
Type
:
Immunology Analyzer
Parameters
:
30 assays
Throughput
:
240 samples / hour
Method
:
CLIA
Open system
:
NO
Others
:
First in South India
 
 
     
 
 

Bayer/Ciba-Corning ACS 180 Plus

     
Type
:
Immunology Analyzer
Parameters
:
31 assays
Throughput
:
180 samples / hour
Method
:
CLIA
Open system
:
NO
     
   
 
 
   

Roche Elecsys 1010

     
Type
:
Immunology Analyzer
Parameters
:
24 assays
Throughput
:
50 samples / hour
Method
:
CLIA
Open system
:
NO
 
         
 
 

Abbott IMx

     
Type
:
Immunology Analyzer
Parameters
:
35 assays
Throughput
:
48 samples / hour
Method
:
FPIA, MEIA
Open system
:
NO
     
   
 
 
   

BACTEC 9050

     
Type
:
Automated blood culturing system
Parameters
:
Enteric / Non-Enteric
Throughput
:
50 samples accomodation
Method
:
Flourescent Technique
Open system
:
NO
 
 

UniCap-100

     
Type
:
Automated specific IgE instrument
Parameters
:
All specific IgE Allergents
Throughput
:
48 samples / 100 tests per run
Method
:
FPIA / Immunocop technology from Pharmacia & Upjohn
Open system
:
NO
     
   
 
 
   

COBAS AMPLICOR Analyzer

     
Type
:
Automated PCR / RTPCR System
Parameters
:
HIV, HCV, HBV / MTB
Throughput
:
48 sample capacity per run
Method
:
Amplification then detection by ELISA
Open system
:
NO
 
 
 
 

FACSCalibur System

     
Type
:
Multipurpose flow cytometer
Parameters
:
CD4, CD3, CD8, HLA B-27, Leukemia Lymphoma panel,
DNA Ploidy, CD34
Throughput
:
 
Method
:
Flow Cytometry
Open system
:
NO
     
   
 

ELISA HIV Hepatitis / ToRCH / TB

 
 
   

Chemwell

     
Type
:
Automated system for ELISA / Chemistry
Parameters
:
All types of ELISA
Throughput
:
96 tests per run
Method
:
ELISA
Open system
:
YES
 
 
     
 

Abbott TDx

     
Type
:
Automated instrument batch analyser for TDM
Parameters
:
Anti-Epileptic Drugs
Throughput
:
20 samples per run
Method
:
FPIA
Open system
:
NO
     
   
         
 
     
 
     
 